Full Library
Evaluating indoor environmental performance of laboratories in a Northern Nigerian university: 33rd PLEA International Conference
Resource type
Conference Paper
Authors/contributors
- Ali, Sani Muhammad (Author)
- Martinson, Brett (Author)
- Al-Maiyah, Sura (Author)
- Brotas, Luisa (Editor)
- Roaf, Susan (Editor)
- Nicol, Fergus (Editor)
Title
Evaluating indoor environmental performance of laboratories in a Northern Nigerian university: 33rd PLEA International Conference
Abstract
Poor environmental comfort in learning spaces can have an impact on the learning capacities of students. It is not unusual to find learning spaces in Nigerian higher institutions in which the indoor environmental qualities do not meet the occupants’ requirements. Despite being in the tropics, where solar radiation is in abundance, Nigerian building industry professionals pay little attention to passive energy utilization. Knowing how buildings perform in the country may appeal to their consciousness in reconsidering this situation. This paper is part of an ongoing study on comfort in higher education facilities involving lecture theatres and laboratories in Bayero University, Kano, Nigeria. Objective and subjective assessments were undertaken during the wet-warm season of August 2016. It reports the assessment conducted on two laboratories, with a view to finding how they perform environmentally in comparison to occupants’ preferences and international comfort standards. Although some of the measured and calculated physical parameters, have not met the thresholds specified by ASHRAE-55 and EN 15251, the respondents expressed their acceptance of the laboratories’ situations subjectively. This is not surprising as these standards are often based on experiments implemented in developed countries, where the severity of the climatic conditions and the culture are dissimilar to sub Saharan Africa.
Date
2017-07-05
Proceedings Title
Proceedings of 33rd PLEA International Conference
Publisher
Network for Comfort and Energy Use in Buildings
Volume
1
Pages
591-598
Short Title
Evaluating indoor environmental performance of laboratories in a Northern Nigerian university
Accessed
26/03/2024, 10:15
Library Catalogue
University of Portsmouth
Citation
Ali, S. M., Martinson, B., & Al-Maiyah, S. (2017). Evaluating indoor environmental performance of laboratories in a Northern Nigerian university: 33rd PLEA International Conference. In L. Brotas, S. Roaf, & F. Nicol (Eds.), Proceedings of 33rd PLEA International Conference (Vol. 1, pp. 591–598). Network for Comfort and Energy Use in Buildings. http://nceub.org.uk/PLEA2017/proceedings/PLEA2017_proceedings_volume_I.pdf
Link to this record